Decision case · RV-01

Two nights, no shore power, every peak declared

Planning capacity established

This case is replayed live from the frozen fixture RV-01 against the current rules engine and catalogue version rv-catalog-2026.08.15.1. It is published as a worked example of the method, not as a purchase recommendation.

1. What was declared

Nights2
Shore powerNone
Air conditioningNo
House batteryNone declared
InverterNone declared
Credited solar300 Wh per day
Fridge600 Wh per day
Lights120 Wh per day
Declared surge — rv-fridge55 W running · 600 W starting

2. The arithmetic

Declared daily need is 720 Wh per day across 2 loads, over 2 nights, against 300 Wh per day of credited solar. The engine's own working:

Declared daily energy720 Wh/day
Declared startup / peak draw605 W
Trip energy (2 night(s))1,440 Wh
Credited recharge (solar + existing alternator)− 420 Wh
Credited existing house battery (0 Wh usable DC × 0.85 delivery)− 0 Wh
Net energy to deliver1,020 Wh
Stored energy required (÷ 0.85 delivery ÷ 0.90 after reserve)1,333 Wh

3. The three gates

Mission energycovered
Daily loopopen
Peak statusproven
Continuous demand60 W
Conservative system peak605 W
Capacity band1,350–1,700 Wh
ArchitecturePortable power station

The peak is proven only because a startup figure was declared for the fridge. Had it been left blank, the case would have abstained from naming any exact product — an undeclared surge is treated as unknown, never as zero.

4. Why the verdict says what it says

  • The trip energy fits inside a single portable station class.

Stable codes: E03-CAPACITY-PORTABLE, E01-MISSION-COVERED, S01-SURGE-DECLARED, P01-NO-PRODUCT-RANKING, L02-LOOP-OPEN, L04-RECHARGE-CREDIT-CAPPED.

5. Limits of this case

  • This architecture calculation on its own names no product, model, price or ranking. An exact SKU is only ever shown separately, by the dated RV catalogue layer, and only when its own evidence and commercial gates pass.
  • This declared trip is sized as a finite mission. It is not sustainable for another day without about 510 Wh/day more credited recharge: 720 Wh/day is used and only 210 Wh/day is credited back. Stored energy alone never closes an indefinite loop.
  • The figures above are the fixture's declared inputs. They are a realistic weekend, not your weekend: a different fridge, a shaded panel or one added device changes the answer.

6. What the engine did about a product

The declared daily recharge loop does not close (510 Wh/day still missing). Energy, continuous power, peak, recharge and connectors must all be proven compatible before an exact SKU is named, so this is an explicit abstention.